What we know about the measurement:

LD Systems DDQ10 is an active liveportable that cost around 1100 USD each.

  • Quality of the measurement data is medium.
  • Origin of the data is LD Systems.
  • Format of the data is a GLL file .
  • -3dB (resp. -6db) point v.s. reference is at 65.0Hz (resp. 63.0Hz).
  • Reference level is normalised to 0.2dB computed over the frequency range [300.0Hz, 5000.0Hz].
  • Frequency deviation is 2.3dB over the same frequency range.
  • Tonality (Preference) Score
    • Tonality (Preference) Score is 4.3 and would be 7.05 with a perfect subwoofer.
      • Details: NBD: ON 0.501, LW 0.431, SP 0.525, PIR 0.432; SM: SP0.917, PIR0.822; LFQ 1.283, LFX 63Hz
    • Tonality (Preference) Score is 5.09 with an EQ and would be 7.75 with a perfect subwoofer and the same EQ.
      • Details: NBD: ON 0.404, LW 0.362, SP 0.439, PIR 0.354; SM: SP0.955, PIR0.92; LFQ 1.283, LFX 60Hz
  • Link to original Review: ah review. .
  • Note: measured with broadband noise at 2m. DUT is a DDQ12 with a DDQ Sub 212. It is unclear to me if the measurements are correct.
LD Systems DDQ10
AutomaticEQ (IIR)
Set preamp gain to: -2.4dB.
Type Freq Q Gain
PK 60.0 2.75 2.98
PK 77.0 2.99 -2.0
PK 310.0 3.0 -4.18
PK 321.0 1.91 3.0
PK 5165.0 1.48 -2.46
PK 7566.0 3.0 2.99
PK 9319.0 2.65 -3.47
Download
This EQ optimise the Harman score and is a good start for far field listening like in your living room.
LD Systems DDQ10
Graphic EQ 15 bands
Set preamp gain to: -0.7dB.
Type Freq Q Gain
PK 25.0 2.14 0.5
PK 40.0 2.14 0.5
PK 63.0 2.14 0.5
PK 100.0 2.14 0.0
PK 160.0 2.14 0.0
PK 250.0 2.14 0.25
PK 400.0 2.14 0.25
PK 630.0 2.14 0.25
PK 1000.0 2.14 0.25
PK 1600.0 2.14 0.5
PK 2500.0 2.14 0.5
PK 4000.0 2.14 0.25
PK 6300.0 2.14 0.25
PK 10000.0 2.14 0.0
PK 16000.0 2.14 0.5
Download
This EQ is designed for a 15 bands graphical EQ.
LD Systems DDQ10
Graphic EQ 31 bands
Set preamp gain to: -1.1dB.
Type Freq Q Gain
PK 20.0 4.32 0.0
PK 25.0 4.32 0.75
PK 31.0 4.32 0.75
PK 40.0 4.32 0.75
PK 50.0 4.32 0.75
PK 63.0 4.32 0.75
PK 80.0 4.32 -0.25
PK 100.0 4.32 0.0
PK 125.0 4.32 0.0
PK 160.0 4.32 0.0
PK 200.0 4.32 0.0
PK 250.0 4.32 0.25
PK 315.0 4.32 -0.25
PK 400.0 4.32 0.0
PK 500.0 4.32 0.0
PK 630.0 4.32 0.0
PK 800.0 4.32 -0.25
PK 1000.0 4.32 -0.25
PK 1250.0 4.32 0.25
PK 1600.0 4.32 0.75
PK 2000.0 4.32 0.5
PK 2500.0 4.32 0.25
PK 3150.0 4.32 0.0
PK 4000.0 4.32 0.0
PK 5000.0 4.32 -0.25
PK 6300.0 4.32 0.0
PK 8000.0 4.32 0.25
PK 10000.0 4.32 -0.5
PK 12000.0 4.32 0.25
PK 16000.0 4.32 0.5
PK 20000.0 4.32 0.0
Download
This EQ is designed for a 31 bands graphical EQ.
Improvement made by adding the above EQ
EQ
AutoEQ
Target v.s. EQ
Target v.s. EQ
Histogram of errors
On Axis (fullrange)
Listening Window (fullrange)
Predicted In-Room Response (fullrange)
LD Systems DDQ10: comparison between EQs
AutomaticEQ
Target v.s. EQ
Comparison betweens various EQs
;